TW CI: 0616-2024 VSL01-PTB05

Summary of calibration parameters

Parameters to be used in ITU files:

* CAL   616 TYPE: PORT ES REL        MJD: 60222 EST. UNCERT.:    0.400 ns

LOC    REM    CI  S      CALR    ESDVAR  ESIG
VSL01  PTB05  616 1     1.000     0.000 0.000
PTB05  VSL01  616 1    -1.000     0.000 0.000

Associated report:

0594-2024_TW_VSL-ROA_v1-0.pdf

Additional remarks:

In the above report, values for this link are provided in the VSL section